RV & Van Solar Power Calculator

Enter your daily energy use in watt-hours, your peak sun hours and your 12V or 24V battery voltage to size the solar array, battery bank and charge controller for an RV, van or boat.

Results are estimates for planning and education, based on your inputs and standard engineering values (AWG resistance, NEC ampacity, resistivity). Electrical work can be dangerous and is governed by the NEC and your local code — verify all sizing with a licensed electrician and your authority having jurisdiction (AHJ). Not a substitute for professional design.

Calculator

Solar array356 W
Battery bank250.0 Ah
Charge-controller current37.0 A
Recommended controller40 A

Formula

Array (W) = daily Wh / (peak sun hours × 0.75 system derate). Battery (Ah) = (daily Wh × autonomy days) / (system V × depth of discharge; 0.8 lithium, 0.5 lead-acid). Charge controller (A) = array W / system V × 1.25, then rounded up to the next standard size.

Worked example

1,200 Wh/day at 4.5 peak sun hours on a 12 V lithium bank with 2 days of autonomy: array = 1,200 / (4.5 × 0.75) = 356 W; battery = (1,200 × 2) / (12 × 0.8) = 250 Ah; controller = 356 / 12 × 1.25 = 37 A, so a 40 A MPPT controller covers it.

Reference table: Peak Sun Hours by US State (NREL Average)

Frequently asked questions

How many watts of solar do I need for my RV or van?
Add up the watt-hours each device uses in a day (watts × hours), then divide by your peak sun hours and a 0.75 system derate that accounts for wiring, controller and panel-temperature losses. A van pulling 1,200 Wh/day in a 4.5-sun-hour location needs about 356 W of panel, which in practice rounds up to a 400 W panel or two 200 W panels. Roof space, shading and how often you drive or run a generator all shift the real number, so treat this as a planning estimate.
How do I size the battery bank for an RV solar setup?
Multiply your daily watt-hours by the number of cloudy or no-drive days you want to ride out (autonomy), then divide by the system voltage and the usable depth of discharge — about 0.8 for lithium (LiFePO4) and 0.5 for lead-acid. For 1,200 Wh/day, 2 days of autonomy and a 12 V lithium bank that is (1,200 × 2) / (12 × 0.8) = 250 Ah. Lead-acid of the same usable size would need roughly 400 Ah because you only safely use half of it.
Should an RV solar system be 12 V or 24 V?
12 V is the default for most vans and RVs because the appliances, fans and water pumps are 12 V native. 24 V becomes attractive on larger rigs (above roughly 1,500–2,000 W of array or long cable runs) because doubling the voltage halves the current, which lets you use smaller, cheaper wire and reduces voltage drop. If you go 24 V you will need a DC-DC converter to feed 12 V loads. This calculator handles either; the battery Ah and controller amps fall as voltage rises.
What size charge controller does the array need?
Controller current is the array wattage divided by the battery voltage, times a 1.25 safety margin for cold-weather over-current: 356 W on a 12 V bank is about 37 A, so a 40 A MPPT controller. MPPT controllers harvest 10–30% more than PWM by converting excess panel voltage into charge current, which matters most when the panel voltage is well above the battery voltage. The tool returns both the raw amps and the next standard controller size.
Why design for the worst month instead of the annual average?
Peak sun hours swing widely between summer and winter. If you live in the rig year-round, sizing on the annual average leaves you short in December when the sun is low and the days are short; use the worst-month figure for the regions you park in. If you only travel in summer or chase the sun, the average — or even a summer figure — is fine. The reference table linked below lists representative peak sun hours by US state.
How do I estimate my daily watt-hours if I do not know them?
Go device by device: multiply each load’s watts by the hours per day you run it, then add them up. A 50 W fridge running effectively 12 hours a day is 600 Wh; a 10 W fan for 8 hours is 80 Wh; lights, a water pump and charging phones add the rest. Sum every item to get the daily watt-hours this calculator asks for. When you are unsure, round up — undersizing the array and battery is the more common and more annoying mistake in a van build.
Does the calculator account for cloudy days and panel losses?
Two ways. The 0.75 system derate baked into the array formula covers everyday losses — wiring resistance, controller inefficiency, dust and the way panels make less power when hot. Cloudy days are handled separately by the days-of-autonomy input, which sizes the battery to carry you through low-sun stretches without charging. For serious off-grid use, combine generous autonomy with a worst-month sun figure, and keep an alternator or shore-power charger as a backup for long overcast spells.

Source: Power balance (daily Wh / peak sun hours, 0.75 system derate), the same method as the off-grid System Size tool, framed for 12/24 V RV systems · All sources